Portable Solar Fridge Freezer

BD/BC-798 — a 798 litre twin lid solar freezer for 10–50 VDC banks: 85 mm of foam, −18 °C holding in a hot room, 1950 × 885 × 935 mm, 24 per 40'HQ, assembled or as a CKD kit.
Send Inquiry
Description

MODEL BD/BC-798 - 798 L twin lid solar freezer  |  1950 × 885 × 935 mm cabinet  |  85 mm foam  |  10–50 VDC input  |  24 V nominal  |  holds −18 °C  |  24 per 40'HQ

Portable solar fridge freezer · eleven numbers on the plate, and the decision each one makes

Eleven numbers decide this refrigerator before it is switched on

A freezer enquiry arrives as one sentence: will it keep my stock frozen? The answer is not in the sentence, and it is not in the photograph. It sits in eleven figures that are printed on the plate, stencilled on the carton and struck into the compressor label - 798 litres, 1950 by 885 by 935 millimetres, 106 kilograms net against 112 gross, 85 millimetres of foam, 24 cartons to a forty foot high cube, minus eighteen degrees, a supply window from ten to fifty volts DC, twenty-four volts nominal, and a refrigerant that is either R134a or R600a depending on the market it ships to. Taken together they answer the question before a price is quoted: whether the route takes the cabinet, whether the bank can feed it, and whether the order fits the container.

This page walks them one at a time, in the order that a wrong decision costs the most money. That order is not the order of the catalogue sheet. It is the order of a delivery: what the cabinet is, whether it goes through the door, what it does with the volts it is given, how much air it needs behind the grille, and how many of them share a container. Every figure below belongs to a BD/BC-798. Nothing here is a rounded marketing number, and nothing here is borrowed from a smaller model in the same line.

Capacity 798 L  |  Cabinet 1950 × 885 × 935 mm  |  Carton 2010 × 895 × 1010 mm  |  Net / gross 106 / 112 kg  |  24 per 40'HQ

BD/BC-798 portable solar fridge freezer, twin lift lids closed, front view

NUMBER ONE · 798 litres - what the volume holds on a Saturday morning, and what it does not

Volume is measured to the liner, so a buyer is really asking a different question: how much frozen stock goes in with both lids shut and the divider in place. In practice a 798 takes twenty-six thirty-litre fish crates with the divider standing, two shifts of a market stall's frozen stock, or around eleven hundred half-litre tubs stood upright along the long compartment. Those are the numbers to hold in your head when the enquiry says eight hundred litres.

The honest limits are three. The centre divider and the wire basket occupy real space. The lids have to close on the load, so nothing may stand above the liner rim. And a cabinet packed to the rim loses the air path that carries cold down between the packets, which leaves the thermostat reading the lid instead of the stock. Load to about four-fifths of the nominal figure and the cabinet behaves predictably for the whole shift.

The 798 is ninety litres larger than the 708 and it pays for that in envelope rather than in cleverness: 165 millimetres longer, 90 millimetres deeper, 45 millimetres taller, and 0.31 square metres more floor. On a stall that is a quarter of a pallet, which is the real cost of the extra volume. What the length buys is reach - two people can work the same cabinet from opposite ends without leaning across a load, and a long compartment takes whole crates instead of loose stock.

Two compartments split by a centre divider, with the wire basket clipped into the right hand compartment, is the standard layout. It matters more on a 798 than on a shorter box: one lid stays shut while the other is opened, so the half of the load that is not being picked over keeps its cold air where it is.

The arithmetic worth doing before the order is litres returned per square metre of floor. The 798 gives back about 462 litres for every square metre it stands on; the 708 gives 499 and the 658 gives 465. That is not a defect, it is what a long shallow cabinet is: capacity bought with footprint. If floor is scarce and the stock is not, order the 708. If the stock is the problem and the floor is a concrete apron, the 798 is the model that carries a whole morning's deliveries without a second cabinet.

NUMBER TWO · 1950 and 885 - the two figures that decide whether the cabinet reaches the room at all

Carried on its long axis, the cabinet presents a cross-section of 885 by 935 millimetres. That, not the length, is what the door sees. A clear opening 900 millimetres wide and 1000 high takes a BD/BC-798 with the lids shut and the castors on, which is how a single leaf door in a shop back room usually measures. Where the opening is 830 the cabinet does not go through, and no amount of tipping helps, because tipping a chest freezer onto its end puts the whole mass of the load path through the compressor pipework.

The corner is the real test, and it is the one nobody measures. Sixteen hundred and fifty millimetres of cabinet plus a turning square narrower than about two thousand millimetres means the unit has to be lifted and walked round, not rolled. A corridor 1200 wide meeting another 1200 wide gives a landing that a 1950 cabinet cannot swing inside; two people, a corner and a hand truck will not change that. Measure the landing, photograph it on a phone, send it with the order, and the delivery becomes a schedule instead of a conversation on the day.

Weight sets the crew. Gross is 112 kilograms, net 106, so two people can rock the cabinet onto a tail lift or a plank and four can carry it upstairs with the castors held clear. The castors themselves are for hard flat ground: yard, apron, shop floor, container floor. On sand, gravel or a rutted track they dig in and the cabinet becomes a four-man lift again, which is why the sites that move seasonally keep two planks with the cabinet instead of a trolley.

If the route fails, the fix is chosen before the container is booked. The 708 in the same line is 165 millimetres shorter and 90 millimetres shallower, and it passes openings the 798 cannot. Sending the larger cabinet anyway and discovering the doorway at the customer's gate is how a first order becomes a claim.

BD/BC-798 portable solar fridge freezer with both lids open, showing the two compartments and the centre divider

What the cabinet does with the volts it is given

Thermostat dial and vent slots on the front panel of a BD/BC-798 solar freezer

NUMBER THREE · −18 and the dial - a thermostat position is not a temperature

The plate on the front of this cabinet carries two indicator lamps and a dial. The lamps report what the controller is doing - supply present, compressor running - and the dial reports nothing at all until somebody puts a thermometer in the load. Minus eighteen is the holding standard for frozen stock, and it is a temperature measured inside the cabinet, not a mark on a knob. Two cabinets set to the same dial position in two different rooms will hold two different temperatures, because ambient, load and airflow all move the result.

The first week settles it. Run the cabinet empty for one night on the site's own bank, lids shut, and put an ordinary fridge thermometer on the floor of each compartment rather than hanging it on the wall. Note the temperature at the start of a compressor run and at the end of it. Then load the stock cold, in one go, and repeat the reading the next morning. If the compartment floor sits at minus eighteen with the load in and the lids shut, the dial is in the right place; if it sits at minus fourteen, move it one step and leave it there for a full day before touching it again. Dial chasing is the fastest way to make a healthy cabinet look faulty.

Two habits keep the number honest. A thermometer lives in the load, not on a shelf bracket, because air temperature swings several degrees between compressor starts. And frost gets a rule of its own: a light even bloom on the liner is normal, five millimetres along the top of the walls is a defrost, and a ridge confined to one end says damp air is finding its way in there - usually a lid left unlatched, sometimes a gasket that has stopped sealing.

Write down three figures for the commissioning sheet: the observed cut-in and cut-out temperatures, the ambient at the time, and the weight of stock loaded. A technician arriving at a complaint six months later can do nothing useful with the sentence "it is not cold enough", and everything with those three numbers.

NUMBER FOUR · 10–50 VDC - why the window is that wide, and why 24 volts is only nominal

The compressor accepts anything from ten to fifty volts DC, and the width of that window is not generosity. A PV bank is a moving source. A twenty-four volt battery that reads 26.4 volts at noon on a short cable can present nineteen volts at four in the afternoon, on a long run, with the compressor pulling. A freezer whose cut-out threshold sits at twenty-two volts spends every afternoon warm, and the owner blames the refrigerant. The window exists so the cabinet keeps running through the sag instead of dropping out of it.

Cable is sized for the low end of the window, never the middle. At half the volts the current doubles for the same cooling, and volt drop is current times resistance, so a run that looks generous at 26 volts can eat four of them at 20. Put the fuse at the battery, not at the cabinet, so a short in the run is protected before it reaches anything expensive, and put the isolator where a person can reach it without moving stock - on this cabinet that is the rocker switch on the compressor end panel.

Twenty-four volts nominal is the standard for this size because it halves the current of a twelve volt system on the same load, which halves the copper. A site already running a twelve volt bank can still feed a 798 inside the window, but the cable and the fuse have to be bought for twelve volt currents, and the installer should say so out loud rather than discover it at commissioning.

Write down four figures before shipping: the array's open-circuit voltage and short-circuit current, the battery chemistry and nominal voltage, the one-way cable length from bank to cabinet, and the lowest voltage the site has ever seen under load. Those four decide whether the cabinet gets the volts it was designed for, and they cost nothing to collect.

Compressor end panel of a BD/BC-798 solar freezer with condenser fan, isolator switch and vent banks

Foam, air and mass: three figures that never appear in a quotation

Wire tube condenser across the rear panel of a BD/BC-798 solar freezer

NUMBER FIVE · 85, 106 and 112 - the foam, the net weight, the gross weight, and the hundred millimetres behind the grille

Eighty-five millimetres of foam on every face is the figure that decides how the cabinet behaves in a hot room. Foam is holdover: it buys time between compressor runs, and it decides how much heat the room can push in through the walls while the compressor is off. The fifty-eight millimetre boxes in the same catalogue are honest cabinets for temperate markets; in thirty-eight degree ambient with eighty per cent humidity they run longer, sweat along the lid frames, and grow frost where the foam is thinnest. The 798 is specified at 85 because most of the volume goes to markets where the ambient is the whole problem.

One hundred and six kilograms net against 112 gross is the handling figure. A crate has to be lifted square by machine, not slid off a tail lift, and on site the cabinet moves on its castors or on a plank. Two hundred kilos of frozen stock inside a hundred and six kilo shell also means the floor matters: a timber mezzanine or a raised deck takes the point load of four castors, and a concrete apron does not care. Ask before delivery where the cabinet will stand for the next five years.

The rear panel is a wire tube grid, and it sheds heat by keeping air moving over the wires. Leave 100 millimetres clear behind it and keep the ends open. A cabinet pushed against a wall, boxed into a counter, or parked with crates at the compressor end runs hotter, runs longer, and eventually trips on its own protection in the middle of the afternoon. This is the single most common installation fault we see, and it is the cheapest one to avoid.

Write down the maximum ambient of the room in the hot month rather than the average, the clearance that will actually exist behind the cabinet rather than the clearance in the plan, and the floor type. Three figures, and they decide whether a correctly built cabinet gets a fair test in its first summer.

NUMBER SIX · 24 per 40'HQ - the container arithmetic, and the box that travels inside the box

Twenty-four cabinets fit a forty foot high cube in single-wall cartons of 2010 by 895 by 1010 millimetres. The 708 loads twenty-six, so the 798 costs two units of container space and a little freight per cabinet, and that difference is worth stating plainly rather than leaving the forwarder to discover it. It is also the reason a mixed container usually beats a pure one: a plan of sixteen 798s and eight 708s fills the same box, serves two customer sizes, and spreads the fixed cost of the shipment across both.

Two handling rules go on the shipping documents. Keep every carton standing, because the compressor hangs from the base plate and a carton laid on its side loads the refrigeration pipework with the mass of the whole cabinet. Stack cartons only on cartons, corners aligned, so no lid ever becomes a bearing surface. Both ends of the journey load by machine; where a tail lift and a hand truck are all the equipment there is, corners get crushed and the claim lands on the importer.

The accessory pack travels clipped inside the cabinet: the basket, a mains lead so the unit can be bench tested on grid power before the bank is touched, and a manual in the destination language. Open it at goods-in, before the packaging is broken down. A missing manual is a three week delay nobody can fix locally, and the pack is the one line on a delivery note that is never photographed.

Write down the quantity per model, the mixed plan if there is one, and the spare parts that travel with the container. A seal, a fan, a controller and a hinge set for every twenty cabinets in service is the ratio that keeps a distributor out of air freight for a five dollar part.

Wire basket, mains lead and manual packed inside a BD/BC-798 solar freezer

BD/BC-798 specification

ItemBD/BC-798
ModelBD/BC-798
TypePortable solar fridge freezer, chest, twin lift lids
Gross volume798 L
Cabinet size1950 × 885 × 935 mm
Carton size2010 × 895 × 1010 mm
Net / gross weight106 kg / 112 kg
Foam thickness85 mm
Temperature−18 °C and below
Power input10–50 VDC wide range, 24 V nominal
RefrigerantR134a / R600a
Compartment layoutTwo compartments, centre divider, wire basket in the right hand side
Loading24 units per 40'HQ
SupplyAssembled cabinet, or CKD / SKD kit for local assembly

The eleven numbers as a purchase checklist

NumberWhat it settlesWhat it costs when it is ignored
798 LCrate count, stock weight, whether one cabinet covers a shiftA second cabinet bought a year early
1950 mmThe corner and the landing on the routeA cabinet that stops at the gate
885 mmDoorway and aisle width the cabinet must passTipping a chest on its end, damaged pipework
935 mmReach into the bottom of the liner, door headroomStock that never gets rotated
85 mmHoldover between compressor runs in a hot roomLonger run times and wet lid frames
−18 °CThe holding standard and the thermometer positionA frozen load that is not frozen in the middle
10–50 VDCArray output, cable size, fuse ratingAfternoon cut-outs blamed on the gas
24 V nominalBank voltage and half the copper of a 12 V siteCable bought for the wrong current
106 / 112 kgHow many people lift, what the floor must carryA cabinet dropped off a tail lift
24 per 40'HQOrder quantity, mixed plan, freight per unitTwo units of space discovered at booking
R134a / R600aWhich gas a local technician must keep on the vanA service call lost to a gas that is not there

Two tables, one page, printed and taped inside the compressor cover: from that point the cabinet documents itself, and whoever opens it in three years begins with figures instead of guesses. A distributor who does this once stops answering the same six questions by email, and stops losing the answers between orders.

BD/BC-798 portable solar fridge freezer outdoors at midday with a ground mounted solar array behind it

WHERE IT COMES FROM - one plant, one parts bin, and a loading plan you can see before you pay

Zhejiang Juka Solar Technology makes DC refrigeration in Hangzhou, and the chest freezer line begins at a 98 litre single lid box and ends at 1388 litre twins. Solar air conditioners, ice makers, display coolers and refrigeration spares come off the same site, so a mixed container is normal rather than a special request, and a gasket ordered for a 798 can travel in the same box as a fan for a display cooler.

For an importer the useful document is not another white cabinet on a white background. It is the loading plan: how many of each volume fill a forty foot box, which models share seals, hinges and controllers, which ship assembled and which are knocked down for local build, and what the reorder looks like once the first container has sold. Ask those four questions in the first email and the second order takes one line to confirm.

WHAT WE NEED FROM YOU - four figures, and the quotation comes back with the array, the cable and the freight inside it, not a cabinet price that stops at the factory gate.

Send the crate count you carry in your busiest week, the narrowest opening and the hardest corner on the way into the room, the sun hours of your worst month, and the bank voltage already on site. The answer names the model that fits, sizes the array and the battery for that location, sketches the mix that fills the box, and puts a sailing date against a BD/BC-798. Samples leave from stock.

Hot Tags: portable solar fridge freezer, China portable solar fridge freezer manufacturers, suppliers, factory, 65mm Foaming Thickness Normal 10v 50vdcsolar Deep Freezer Single Door BD BC 208, 85mm Foaming Thickness Normal 10v 50vdcsolar Deep Freezer Double Doors BD BC 508, commercial solar freezer, cool box solar freezer, hybrid 10 50vdc deep freezer 65mm, off grid solar freezer