MODEL BD/BC-708 - 708 L twin lid solar freezer | 1785 × 795 × 890 mm cabinet | 85 mm foam | 10–50 VDC input | 24 V nominal | holds −18 °C | 26 per 40'HQ
Solar powered portable freezer · nine stages from the carton to the cold store
This page follows one cabinet from the packing line to the third one ordered
Most product pages describe a box as if it had always been standing where it is. This one does the opposite. It follows a BD/BC-708 through the nine stages that decide whether the unit works in the place it is going: the crate it leaves in, the door it has to pass, the pad under it, the array that feeds it, the first pull down, the way a shift loads it, the daily cycle, the parts a technician will eventually change, and the reason the same buyer orders a second and then a third.
The order is deliberate. Nearly every complaint we see on a solar freezer has nothing to do with the freezer. It comes from a crate that was opened with a crowbar, a cabinet pushed against a wall so the condenser cannot breathe, an array that collapses in voltage at four in the afternoon, or a box filled with warm stock on the first day and blamed for the week after. Read the nine stages in order and those four failures are designed out before the container is booked.
Capacity 708 L | Cabinet 1785 × 795 × 890 mm | Carton 1835 × 895 × 965 mm | Net / gross 86 / 91 kg | 26 per 40'HQ

BEFORE STAGE ONE · the name - why a 708 litre cabinet is sold as portable, and what portable honestly means here
Portable in this range means one thing only: the cabinet can be moved by people rather than by a crane. Two castors at the compressor end, two at the far end, a shell that weighs 86 kg dry, and a length of 1785 mm that passes a standard double door when the lids are shut. That is the whole claim. It is not a cooler you carry, it is not a box that rides on a pickup bed for a hundred kilometres, and a customer who expects either will be disappointed in week one.
What the word is really for is the site that changes. A market stall that moves twice a year, a fishing camp that shifts with the season, a clinic whose cold room is on the second floor and whose lift is 800 mm wide, a farm kitchen that sits in a different shed each harvest. In those places a built-in cold room is a mistake and an upright chiller is a staircase problem. A chest cabinet on wheels, lifted onto a truck by four people and a plank, is the practical answer - and 708 litres is the largest volume in the range that still answers it without a forklift.
The geometry behind that is worth spelling out because it explains the shape of the cabinet. At 1785 mm long and 795 mm deep the unit covers 1.42 square metres of floor and returns about 499 litres for every square metre it occupies, which is the highest ratio in the family: the 608 returns 457 and the 658 returns 465. The volume comes from length rather than depth, so the cabinet can still be pushed through a doorway one person wide and can still be reached from the long side by someone standing at the front.
STAGE ONE · the crate - one carton, 56 mm of clearance, and the reason the manual is inside the box
The cabinet leaves in a single wall carton measuring 1835 × 895 × 965 mm against a cabinet of 1785 × 795 × 890 mm. That difference is the whole protection budget: 25 mm of foam at each end, 50 mm at each side, 75 mm above the lid and the rest below the base. It is enough for a container that is loaded and unloaded by machine and not enough for a carton that is dropped off a tail lift, which is why the sides carry the usual handling marks and why the gross weight is printed as 91 kg against 86 kg net.
Inside, in the wire basket, sits the accessory pack: the basket itself, a mains lead for bench testing before the DC bank is connected, and the manual in the buyer's language. Everything a commissioning technician needs on day one is in that basket, because the alternative is a site waiting three weeks for a document that was left in the crate tray. Check the basket before the carton goes to the recycler; it is the one part of the delivery nobody photographs.
Loading is 26 cabinets per 40 foot high cube, stacked by the forwarder's plan rather than ours. Two rules travel with the container paperwork. Cartons stay upright, because the compressor is mounted to the base plate and a carton on its side puts the whole cabinet weight on the pipework. And nothing rides on top of a carton except another carton, square on the corners, so the lids are never the bearing surface.

The last kilometre is where most deliveries go wrong
STAGE TWO · the doorway - 800 mm of opening, 1785 mm of cabinet and two people who did not bring a trolley
A BD/BC-708 is 795 mm deep and 890 mm high. The depth is the number that decides the delivery. A single leaf door, a lift opening, a corridor bend, a stairwell landing: anything under about 830 mm clear will not take the cabinet on its castors, and anything under 795 mm will not take it at all, not even tipped. Ask for the narrowest clear opening on the route before the truck is booked. It costs one email and it has saved more deliveries than any piece of packaging we make.
If the opening is tight but not impossible, the cabinet goes through on its side, on a plank, at four lifting points: under the base at each corner. Never lift by the lid handles or by the lid edge. The handle is a die cast part screwed to a lid skin; it will take a person's pull every day for a decade and it will not take the weight of 86 kg plus the shock of a set down. Two people can carry the cabinet level for a short distance. Three is better on a stair, one at the load and two lifting from below.
Once inside, the cabinet should sit on a flat surface. A concrete slab, a tiled floor, a timber deck with a joist under each castor is fine. Loose sand, a sloping apron or a corrugated steel sheet is not, because a cabinet that rocks on three castors flexes its base plate every time a lid is dropped, and the pipework at the compressor end is where that flexing eventually shows up as a leak.

STAGE THREE · the air - the rear panel needs a hand's width, and a hot room asks for more than the manual says
The condenser on this cabinet is a wire tube grid across the whole rear panel, and it rejects heat by moving air across the wires. Standing it against a wall with 20 mm of gap is the single most common installation mistake on any chest freezer, and on a solar unit it is expensive: every degree the condenser cannot shed comes back as compressor run time taken out of the battery.
Give the rear panel at least 100 mm of clear air and keep the front and sides open enough that the room can turn over. Do not box the cabinet into a counter. Do not park sacks, crates or a spare carton behind it, which is where they always end up. The vent bank and the condenser fan sit on the end panel, so the end with the thermostat also needs to breathe; a cabinet pushed into a corner has one end starved and the other end in dead air.
Above about 38 °C ambient the arithmetic changes. A chest freezer holding minus 18 in a 25 °C room is running at a comfortable lift; the same cabinet in a 42 °C tin roof shed is running a much longer duty cycle and drawing more from the bank for the same cold. That is not a fault, it is physics, and the answer is either shade and cross-ventilation over the cabinet or a larger array. A cabinet under a roof vent will outperform a bigger cabinet in the sun every time.
Dust is the slow version of the same problem. In a flour mill, a feed store, a cement yard or anywhere with airborne fibre, the condenser wires mat over in a season and the cabinet starts running long. A soft brush down the wires every few months, with the cabinet unplugged or the DC isolator open, restores most of the lost performance. Put it in the maintenance schedule next to the door gasket; it takes ten minutes and it is the difference between a five year compressor and a nine year one.
STAGE FOUR · the bank - 10 to 50 volts in, 24 volts nominal, and why the wide window matters more than the number
The controller on the end panel takes anything from 10 to 50 VDC and is set up for a 24 V nominal bank. That window is not decoration. A nominal 24 V array sits at 26 to 28 V in good sun, drops to 24 V under a load step, sags to 21 or 22 V when a cloud passes and the battery is half empty, and climbs past 29 V during an equalise charge. A fixed 24 V controller protects itself against all of that by switching off, which is exactly what nobody wants at four in the afternoon. The wide window lets the compressor keep running through the sag and pick up again when the sun returns, so the cold holds instead of cycling.
Wiring is where the money is usually saved and where the performance is usually lost. Size the run from the bank to the cabinet for the current at the lowest voltage in the window, not the nominal one, and keep the cable short. A cabinet on a 6 metre run of undersized cable sees a volt drop that looks like a flat battery to the controller, and the site blames the freezer for a fault that lives in the cable. Fuse at the battery end, not at the cabinet end, and put a DC isolator where a technician can reach it without moving the unit.
Polarity matters. The mains lead in the accessory pack is for bench testing and for a site that has grid; a DC site runs from the bank through the DC terminals. Connect the bank with the isolator open, check the polarity twice, and only then close. A reversed connection on a DC compressor controller is a dead controller, and it is the one failure that packaging, documentation and a warning label cannot prevent on their own.

Two practical notes that come up on almost every site visit. First, a solar freezer should not share a charge controller with a lighting circuit that switches large loads at dusk; the voltage dip at switch-on is read as a low battery and the cabinet drops out for the evening. Second, if the site runs a generator as backup, do not feed the cabinet from it directly unless the generator output is steady, because a small generator's voltage wanders outside the window under load and the controller will protect itself repeatedly. Charge the bank and let the bank run the freezer.
Two days that decide the next five years: the first pull down and the first load
STAGE FIVE · first pull down - run it empty, overnight, with nothing inside and nobody opening the lids
A new cabinet goes onto the pad, gets 100 mm of air at the back, gets connected and then gets left alone. Empty, lids shut, running overnight. That first pull down does three things at once: it proves the controller and compressor work from the site's own bank rather than from a bench supply, it drives the liner down from ambient to working temperature with no load to hide a weak charge, and it gives the technician a baseline reading to compare against in six months.
Write the numbers down while the cabinet is empty. Ambient temperature in the room, bank voltage before start, bank voltage under load two hours in, the thermostat setting, and the time taken to reach the cut-out point. A sheet of paper taped inside the compressor cover with those five figures on it is worth more than any service contract, because the next person to open that cover knows what normal looked like on day one.
Then load it cold, in stages, and never with warm stock. A 708 litre box filled with ambient produce on its first morning will run for a day and a half, pull the bank well below its comfortable depth overnight, and teach the owner that solar freezers are weak. The same cabinet loaded with stock that is already near freezing, in two or three passes over a day, settles into a short duty cycle and never looks back. If the stock arrives warm - a delivery from a boat, a market run, a harvest - pre-chill it in the shade overnight or load the cabinet in the coolest part of the day, not at noon.
The thermostat should be set once, by the technician, and then left. The setting that holds a safe minus 18 at the warmest part of the load is the right one, and it is rarely the coldest position on the dial. Running the cabinet further down than it needs costs battery capacity every single day of its life to buy a margin nobody eats.

STAGE SIX · loading - two small openings instead of one big one, and what that is worth on a hot afternoon
Chest freezers lose their cold through the top, and a 708 litre cabinet with a single full length lid would lose a great deal of it every time somebody reached for one packet. The twin lid layout splits the opening into two, and the divider under it splits the volume, so a shift can work out of one side while the other stays shut. On a solar cabinet that is not a convenience feature, it is a power feature: every minute a lid is open is compressor time charged to the array.
Load by weight and by habit, not by volume. Heavy frozen stock goes in first and low, because mass at the bottom is what holds the cabinet through a cloudy day. The wire basket in the right hand compartment is for the things that get taken out twenty times a shift - ice, sachets, the day's portions - so the lids open for seconds rather than minutes. Anything that needs to be found by touch belongs in the basket, anything that is stock belongs underneath it.
Leave the liner walls clear. A cabinet packed so tightly that packets touch the walls loses the air gap that lets cold move around the load, and the thermostat reads a temperature that is not the temperature of the middle of the box. Leave a hand's width at the ends and do not stack above the load line moulded into the liner. A box that is 90 percent full and loosely packed holds cold better than one that is 100 percent full and jammed.
Two habits are worth training into whoever loads it. Nothing hot goes in, not a pot, not a just-cooked batch, not a warm delivery. And the lid is closed and latched every time, including the thirty seconds between two trays; a lid left resting open is a compressor asked to cool the room.
STAGE SEVEN · the daily cycle - gasket, frost line and the ten minute weekly check that prevents most service calls
The lid is where a chest freezer either holds its cold or quietly loses it. This one is foam filled, with the grid pattern visible on the inside skin, and it seals on a continuous gasket against the cabinet rim. The gasket is the part that ages. Heat, dust, sun and the habit of closing a lid on a packet that sticks up all take a toll, and the first symptom is not a warm cabinet but a wet rim and a longer duty cycle.
The check takes a minute and needs no tools. Shut the lid on a strip of paper at four points around the rim; if the paper slides out without drag, the seal is not sealing at that point. Wipe the gasket with a damp cloth weekly, look for cracks at the corners, and check that the hinge blocks still pull the lid down evenly, because a lid that sits a millimetre high along one edge passes more air than a worn gasket ever will.
Frost is the other daily signal. A thin even film on the liner is normal. A thick ridge along the top of the walls, or ice building at one end only, means moist air is getting in - usually the gasket, sometimes a lid left unlatched overnight. Defrost when the frost gets to about 5 mm, with the cabinet switched off, the stock moved into a second box or a insulated blanket, and the lids open. Never chip at it with a blade. A plastic scraper and warm water, then dry the liner completely before restart.

A working rhythm that suits most sites: load in the morning while the bank is filling, take stock out at the end of the shift while the sun is still up, and leave the cabinet shut overnight. A cabinet that is opened at 21:00 is running on battery, and the same cabinet opened at 15:00 is running on sunshine. It sounds trivial and it changes the size of the array a site needs.
What a technician will actually change, in the order it happens
STAGE EIGHT · service - five parts on a shelf, and a cabinet that does not need to leave the site for any of them
The end panel is the service hatch for everything electrical. Behind it sit the controller and thermostat, the condenser fan and the terminal block, and all three are reachable from the outside with the cabinet in place. That was a design decision rather than a happy accident: on a site four hours from a town, the difference between a part that can be posted and swapped and a cabinet that has to be returned is the difference between a three day repair and a six week one.
The parts that fail, in the order we see them. Door gasket first, because it is a wearing part and nobody thinks of it as one. Condenser fan second, usually dust or a dry bearing, and it announces itself with a noise before it stops. Thermostat or controller third, normally after a lightning season or a badly connected bank. Hinge and handle fourth, almost always from being used as a lifting point. Compressor last, and when a compressor goes at three years rather than ten it is nearly always a site that never cleared the condenser.
A distributor who stocks one gasket, one fan, one controller and one hinge set per twenty cabinets in the field can close nine out of ten service calls without a second visit. The same spares cover the 608 and the 658 in most cases, which is why the range shares a component list even where it does not share a footprint.
STAGE NINE · the second cabinet - the point where a buyer stops ordering a freezer and starts planning a cold store
Almost nobody runs one of these alone. The first cabinet proves the site, the second one goes next to it, and by the third the conversation has changed from which model to how the bank, the array and the spares are shared. A 708 sits comfortably in that progression because 26 units fill a 40 foot high cube and because the cabinet is the widest volume available without going up to a 1388 litre twin, so a distributor can grow a site in steps that each still fit through the same door.
When the site does grow, keep the cabinets on a common bank and separate isolators. One cabinet going down for a gasket should never take the other two with it, and a technician working on one needs to be able to lock out that one only. Keep the spare parts in one box with the manual, the wiring diagram and the day one readings for each serial. That box is the difference between a cold store that scales and three freezers that each fail on their own schedule.
Beyond the cabinets themselves, the practical questions are the ones a container plan answers: how many units of which model, whether they ship assembled or as knocked down kits for a local line, whether cartons, rating plates and manuals carry the buyer's brand, and which spares travel in the same container. Those four answers decide the price per litre as much as the cabinet does, and they are all settled before the proforma rather than after it.
BD/BC-708 specification
| Item | BD/BC-708 |
| Model | BD/BC-708 |
| Type | Solar powered portable freezer, chest, twin lift lids |
| Gross volume | 708 L |
| Cabinet size | 1785 × 795 × 890 mm |
| Carton size | 1835 × 895 × 965 mm |
| Net / gross weight | 86 kg / 91 kg |
| Foam thickness | 85 mm |
| Temperature | −18 °C and below |
| Power input | 10–50 VDC wide range, 24 V nominal |
| Refrigerant | R134a / R600a |
| Compartment layout | Two compartments, centre divider, wire basket in the right hand side |
| Loading | 26 units per 40'HQ |
| Supply | Assembled cabinet, or CKD / SKD kit for local assembly |
The nine stages as a checklist
| Stage | What to settle before the order | Number to write down |
| 1. Crate | Cartons upright, nothing stacked on the lids, basket checked on arrival | 1835 × 895 × 965 mm |
| 2. Doorway | Narrowest clear opening on the route, lifting points agreed | 795 mm depth, 890 mm height |
| 3. Air | 100 mm clear behind the condenser, no crates parked at the end panel | Ambient temperature |
| 4. Bank | Cable sized at the lowest voltage in the window, fused at the battery | 10–50 VDC input |
| 5. Pull down | Run empty overnight from the site's own bank before loading | Volts under load, hours to cut out |
| 6. Loading | Cold stock only, basket for fast movers, liner walls clear | 708 L, two compartments |
| 7. Daily cycle | Gasket paper test weekly, defrost at 5 mm of frost, lids latched | Thermostat setting |
| 8. Service | One gasket, fan, controller and hinge set per twenty cabinets in the field | Serial number series |
| 9. Growth | Common bank, separate isolators, spares in one box per serial | 26 units per 40'HQ |
Print the two tables, tape them inside the compressor cover, and the cabinet carries its own commissioning history for whoever opens it next.

WHO BUILDS IT - a DC refrigeration plant in Hangzhou, and a container plan rather than a catalogue page
Zhejiang Juka Solar Technology builds DC refrigeration in Hangzhou, and the chest freezer programme runs from a 98 litre single lid box up to 1388 litre twins. Around it the same plant builds solar air conditioners, ice makers, display coolers and refrigeration parts, which is why a container rarely leaves with one model in it and why the spares list is written across the range rather than per product.
For an importer the useful part is not the photograph, it is the plan behind it: which volumes fill a container, which cabinets share a gasket and a hinge, which models ship assembled and which as kits, and what the second order looks like when the first one sells through. That is the conversation we would rather have on the first email than on the fifth.
FOUR THINGS TO SEND US - volume, route, sun hours and bank voltage - enough for a quotation that includes power and freight instead of a price for a cabinet on its own.
Tell us how many litres of frozen stock you hold in your busiest week, the narrowest door the cabinet has to pass, the sun hours in your worst month rather than your best, and the bank voltage you already run if you run one. The reply gives the model that fits the space, the array and battery arithmetic for that site, the mix that fills the container and the date the 708 can be on the water. Sample cabinets come out of stock.
Hot Tags: solar powered portable freezer, China solar powered portable freezer manufacturers, suppliers, factory, 65mm Foaming Thickness Normal 10v 50vdcsolar Deep Freezer Single Door BD BC 208, 65mm Foaming Thickness Normal 10v 50vdcsolar Deep Freezer Single Door BD BC 68, 85mm Foaming Thickness Normal 10v 50vdcsolar Deep Freezer Double Doors BD BC 508, commercial solar freezer, cool box solar freezer, off grid solar freezer